fufasad.blogg.se

Aeon labs z-stick plus
Aeon labs z-stick plus





aeon labs z-stick plus
  1. Aeon labs z stick plus serial#
  2. Aeon labs z stick plus update#
  3. Aeon labs z stick plus plus#

Aeon labs z stick plus serial#

The Leviton VRCOP serial device in the basement also covers all of the Z-Wave devices. The RF range covers all of my Z-Wave test devices inside (to 3 floors down) and outside. Here I use a ZWave dot me GPIO device inside of a RPi2 mounted in the attic of the home connected to the network via a POE connection. Zigbee devices are still being tested connecting to 3 Zigbee touchscreens and 1 Leviton serial ZIM module. Z-Wave devices connect to the Z-Wave Me GPIO device and a Leviton serial VRCOP. There is a UPB repeater in my electrical panel. All light switch boxes have a hot wire, neutral, load and ground to box. Concrete walls are not RF friendly.Ĭurrently utilizing X10, UPB, Z-Wave and Zigbee.

Aeon labs z stick plus plus#

You may have a defective smart-stick plus and or a defective Aeon labs Z-Wave stick. Here I had tried with a normal smart stick aeon labs but the devices were losing signal continuously then I changed with a smart stick plus aeon labs but I still have difficulty connecting or return signal from devices Z-Wave received "003 - Setpoint Thermostat" heat setpoint is 21.I have however only four devices all in the space of 10 meters where it uses a smart-stick plus (aeon Labs) but I have many connection problems. Z-Wave received "003 - Setpoint Thermostat" units changed to ☌

Aeon labs z stick plus update#

Z-Wave received "003 - Setpoint Thermostat" temperature update to 19.66 ☌ Z-Wave sent "003 - Setpoint Thermostat" cool setpoint status request Z-Wave sent "003 - Setpoint Thermostat" heat setpoint status request Z-Wave sent "003 - Setpoint Thermostat" temperature status request Z-Wave Syncing - created device "003 - Setpoint Thermostat" Z-Wave Syncing - retrieved battery level of 67% Z-Wave Syncing - synced server clock to module (18:05, Sunday)

aeon labs z-stick plus

Z-Wave Syncing - device "003 - Setpoint Thermostat" wake interval changed to 60 minutes Z-Wave Syncing - retrieved wake interval of 30 minutes Z-Wave Syncing - retrieved class hierarchy: Routing Slave : Thermostat : Setpoint Thermostat (04 : 08 : 04, base 43) Z-Wave Syncing - retrieved protocol version 3.67, app version 1.00 Z-Wave Syncing - retrieved manufacture and model names: Danfoss - 0002, Setpoint Thermostat - 0115A010 Lol I just tried yet again and it has connected this time:

aeon labs z-stick plus

The fact that I cant seem to get it to talk to the ZStick suggests I am doing something wrong Module might be asleep, or is unreachable. Z-Wave Error Timeout waiting for "003 - Setpoint Thermostat". Z-Wave found module included in controller with no matching device (missing or disabled): 003 - Setpoint Thermostat Z-Wave connected to Z-Wave 3.95 static controller interface on /dev/cu.usbmodem1411 (firmware 1.00) Interface Failure lost connection with interface Z-Wave Error silently retrying serial connection every 5.0 seconds Z-Wave Error Z-Wave 3.95 static controller might be disconnected Z-Wave Error serial port communication error: read failed: Device not configured Z-Wave Error No response from "003 - Setpoint Thermostat". Z-Wave Error Syncing - failed to assign return route Z-Wave Syncing - assigning return route to "003 - Setpoint Thermostat" Z-Wave Syncing - retrieved module neighbors list: - none. Z-Wave Syncing - started for "003 - Setpoint Thermostat" Just tried to include the device again and log window says The engineering document with detailed info can be found at. Indigo has not support for this but changing parameter 220 of the Z-Wave stick from max 10 for maximum RF power level down to 1 would set it to the lowest power level. MAX RF power always on unless the user/software changes it. PA Mode: Seems to be enabled by default, i.e. Manual.pdf for the Z-Wave.ME UZB1 stick are measured.Īeon Labs said they will get back with me with actual measured specs (if possible but I guess they should be available to get through the certification process). Remember though that the specs above are on chipset level and I am not sure how the specs at. So the ZW090 from Aeon Labs is somewhat stronger in TX compared to Z-Wave.ME UZB1 stick but somehwat weaker in RX.  Transmit power with SAW filter up to +4dBm (compared to +1dBm for Z-Wave.ME UZB1 stick)  Receiver sensitivity with SAW filter down to -103dBm 9.6kbps (compared to -104dBm for the Z-Wave.ME UZB1 stick) These are the specs according to the chipset used on the Z-Wave stick: Got back an answer from Chris Cheng at Aeon Labs yesterday evening.